MG-INDUSTRIAL Complete Factory Cooling System Complete Systems
The MG-INDUSTRIAL system is a dual-pump, 150-bar misting installation for factory and warehouse cooling up to 10,000 m². Two MG-PRO 1500 stations run in N+1 redundancy across 400 heavy-duty nozzles and 1,000 m of 316L tubing, with a dust-suppression mode and a 65°C ambient rating.
Heavy-duty misting for factories, warehouses, and industrial facilities up to 10,000 m²
Designed for the most demanding industrial environments. Dual redundant MG-PRO 1500 pump stations, 400 heavy-duty nozzles, 1,000 meters of tubing, and industrial-grade filtration. Includes dust suppression mode and high-temperature operation up to 65°C ambient.
Where It Is Used
- Factory floors and assembly halls: Nozzle lines above workstations lower the temperature at the worker while the hall itself stays hot.
- Warehouses and logistics hubs: Works under high ceilings and covers storage aisles without ducting that consumes floor space.
- Mining and coal yards: Coarse-droplet dust-suppression mode fixes airborne dust at material handling points.
- Steel and foundry areas: The 65°C ambient rating allows operation close to intense radiant heat sources.
- Large greenhouses and livestock farms: Evaporative cooling with 10-stage industrial filtration protects nozzles on hard well water.
Environments served
- Factory floors and assembly halls
- Warehouses and logistics hubs
- Mining and coal yards
- Steel and foundry areas
- Large greenhouses and livestock farms
Core Parameters
| Coverage Area | Up to 10,000 m² |
|---|---|
| Pump Stations | 2x MG-PRO 1500 (N+1 redundant) |
| Nozzle Count | 400 (expandable to 800) |
| Tubing | 1,000m 316L SS included |
| Cooling Capacity | Up to 15°C reduction |
| Dust Suppression | Yes, dedicated mode |
| Max Ambient Temp | 65°C |
| Water Treatment | 10-stage industrial system |
| Power | 2x 380V 3-phase, 5.5 kW each |
| Protocols | Modbus, OPC UA, MQTT |
| Duty Cycle | 24/7 continuous rated |
| Installation | Engineer-supervised, 2-3 weeks |
MG-INDUSTRIAL system vs Evaporative cooler (swamp cooler)
| MG-INDUSTRIAL system | Evaporative cooler (swamp cooler) | |
|---|---|---|
| Coverage | 10,000 m² from a piped nozzle network | 150-250 m² per portable unit |
| Ceiling height | Works under 12 m ceilings; nozzles mounted at 2.5-6 m | Needs low ceilings to reach the floor |
| Redundancy | N+1 dual pump stations keep mist flowing during service | Single unit; no coverage when it fails |
| Dust suppression | Dedicated coarse-droplet mode for airborne dust | Not designed for dust |
| Ambient limit | Rated to 65°C ambient | Performance collapses above 40°C in humid air |
| Floor space | Pump room plus overhead lines | Occupies floor area with ducting |
Key Features
- Dual redundant 150 bar pump stations (N+1 configuration)
- 400 heavy-duty ceramic nozzles with reinforced housing
- 1,000m industrial-grade 316L tubing
- Dust suppression mode with larger droplet option
- Industrial 10-stage water treatment system
- High-temp operation rated to 65°C ambient
- 24/7 continuous duty cycle rated
- SCADA integration with OPC UA protocol
MG-INDUSTRIAL Complete Factory Cooling System FAQ
How does the MG-INDUSTRIAL Complete Factory Cooling System high-pressure misting system work?
The MG-INDUSTRIAL Complete Factory Cooling System uses a 150-bar high-pressure pump to force water through 0.15mm ceramic nozzles, creating 5-15 micron droplets. These micro-droplets flash-evaporate in mid-air, absorbing 2,257 kJ of heat per liter of water. The result is 5-15°C cooling without wetting any surfaces.
What cooling performance can I expect from this system?
In controlled testing, 100Cooling high-pressure systems achieve 5-8°C actual temperature reduction and 8-15°C in perceived cooling. Performance depends on ambient humidity — best results in dry to moderately humid climates (RH below 70%). Each installation includes a site-specific performance estimate from our engineering team.
What maintenance is required for the misting system?
Minimal maintenance required: nozzle inspection every 6 months, filter cartridge replacement annually, pump oil change every 2,000 operating hours. The MG-IOT HUB provides proactive remote monitoring and sends automated maintenance alerts. Most installations run 12-18 months between professional service visits.
What warranty coverage is included with this system?
The MG-INDUSTRIAL Complete Factory Cooling System includes a 5 years (pumps), 3 years (nozzles). Our comprehensive warranty covers all pump station components, nozzles, and controllers. It includes parts replacement and remote technical support, with on-site service available through our certified partner network in 25+ countries.
How is the system installed and what are the requirements?
Installation is handled by our certified partner network across 25+ countries. The system requires a standard water connection, 220V/380V power supply, and structural mounting points for nozzles. Our 5-stage integrated filtration handles most water sources. Typical installation takes 2-5 days depending on site size. We provide comprehensive installation documentation and remote supervision.
Engineering Resources
Learn more about misting technology, selection criteria, and ROI
Need a Custom Configuration?
Our engineering team can design a bespoke system for your specific space, climate, and budget.
Get Engineering Consultation