Back to Products
MG INDUSTRIAL COMPLETE

MG-INDUSTRIAL Complete Factory Cooling System Complete Systems

The MG-INDUSTRIAL system is a dual-pump, 150-bar misting installation for factory and warehouse cooling up to 10,000 m². Two MG-PRO 1500 stations run in N+1 redundancy across 400 heavy-duty nozzles and 1,000 m of 316L tubing, with a dust-suppression mode and a 65°C ambient rating.

Heavy-duty misting for factories, warehouses, and industrial facilities up to 10,000 m²

Designed for the most demanding industrial environments. Dual redundant MG-PRO 1500 pump stations, 400 heavy-duty nozzles, 1,000 meters of tubing, and industrial-grade filtration. Includes dust suppression mode and high-temperature operation up to 65°C ambient.

$35,000Starting From
8-12 weeksLead Time
5 years (pumps), 3 years (nozzles)Warranty

Where It Is Used

  • Factory floors and assembly halls: Nozzle lines above workstations lower the temperature at the worker while the hall itself stays hot.
  • Warehouses and logistics hubs: Works under high ceilings and covers storage aisles without ducting that consumes floor space.
  • Mining and coal yards: Coarse-droplet dust-suppression mode fixes airborne dust at material handling points.
  • Steel and foundry areas: The 65°C ambient rating allows operation close to intense radiant heat sources.
  • Large greenhouses and livestock farms: Evaporative cooling with 10-stage industrial filtration protects nozzles on hard well water.

Environments served

  • Factory floors and assembly halls
  • Warehouses and logistics hubs
  • Mining and coal yards
  • Steel and foundry areas
  • Large greenhouses and livestock farms

Core Parameters

Technical specifications for MG-INDUSTRIAL Complete Factory Cooling System
Coverage AreaUp to 10,000 m²
Pump Stations2x MG-PRO 1500 (N+1 redundant)
Nozzle Count400 (expandable to 800)
Tubing1,000m 316L SS included
Cooling CapacityUp to 15°C reduction
Dust SuppressionYes, dedicated mode
Max Ambient Temp65°C
Water Treatment10-stage industrial system
Power2x 380V 3-phase, 5.5 kW each
ProtocolsModbus, OPC UA, MQTT
Duty Cycle24/7 continuous rated
InstallationEngineer-supervised, 2-3 weeks

MG-INDUSTRIAL system vs Evaporative cooler (swamp cooler)

MG-INDUSTRIAL Complete Factory Cooling System compared with Evaporative cooler (swamp cooler)
 MG-INDUSTRIAL systemEvaporative cooler (swamp cooler)
Coverage10,000 m² from a piped nozzle network150-250 m² per portable unit
Ceiling heightWorks under 12 m ceilings; nozzles mounted at 2.5-6 mNeeds low ceilings to reach the floor
RedundancyN+1 dual pump stations keep mist flowing during serviceSingle unit; no coverage when it fails
Dust suppressionDedicated coarse-droplet mode for airborne dustNot designed for dust
Ambient limitRated to 65°C ambientPerformance collapses above 40°C in humid air
Floor spacePump room plus overhead linesOccupies floor area with ducting

Key Features

  • Dual redundant 150 bar pump stations (N+1 configuration)
  • 400 heavy-duty ceramic nozzles with reinforced housing
  • 1,000m industrial-grade 316L tubing
  • Dust suppression mode with larger droplet option
  • Industrial 10-stage water treatment system
  • High-temp operation rated to 65°C ambient
  • 24/7 continuous duty cycle rated
  • SCADA integration with OPC UA protocol

MG-INDUSTRIAL Complete Factory Cooling System FAQ

How does the MG-INDUSTRIAL Complete Factory Cooling System high-pressure misting system work?

The MG-INDUSTRIAL Complete Factory Cooling System uses a 150-bar high-pressure pump to force water through 0.15mm ceramic nozzles, creating 5-15 micron droplets. These micro-droplets flash-evaporate in mid-air, absorbing 2,257 kJ of heat per liter of water. The result is 5-15°C cooling without wetting any surfaces.

What cooling performance can I expect from this system?

In controlled testing, 100Cooling high-pressure systems achieve 5-8°C actual temperature reduction and 8-15°C in perceived cooling. Performance depends on ambient humidity — best results in dry to moderately humid climates (RH below 70%). Each installation includes a site-specific performance estimate from our engineering team.

What maintenance is required for the misting system?

Minimal maintenance required: nozzle inspection every 6 months, filter cartridge replacement annually, pump oil change every 2,000 operating hours. The MG-IOT HUB provides proactive remote monitoring and sends automated maintenance alerts. Most installations run 12-18 months between professional service visits.

What warranty coverage is included with this system?

The MG-INDUSTRIAL Complete Factory Cooling System includes a 5 years (pumps), 3 years (nozzles). Our comprehensive warranty covers all pump station components, nozzles, and controllers. It includes parts replacement and remote technical support, with on-site service available through our certified partner network in 25+ countries.

How is the system installed and what are the requirements?

Installation is handled by our certified partner network across 25+ countries. The system requires a standard water connection, 220V/380V power supply, and structural mounting points for nozzles. Our 5-stage integrated filtration handles most water sources. Typical installation takes 2-5 days depending on site size. We provide comprehensive installation documentation and remote supervision.

Need a Custom Configuration?

Our engineering team can design a bespoke system for your specific space, climate, and budget.

Get Engineering Consultation