MG-PRO 1500 High-Pressure Pump Station Pump Stations
The MG-PRO 1500 is a 150-bar high-pressure pump station rated for continuous 24/7 duty. Its 5.5 kW variable-frequency drive and 316L stainless steel pump head deliver 8-25 L/min to as many as 200 ceramic nozzles, making it the pressure source behind commercial outdoor cooling, dust suppression and mosquito control installations up to 5,000 m².
150 bar industrial-grade misting pump with VFD motor control
The MG-PRO 1500 is our flagship high-pressure pump station engineered for continuous 24/7 operation in the most demanding environments. Features a 5.5 kW variable frequency drive motor, 316L stainless steel pump head, and intelligent pressure regulation system that maintains consistent output across 200+ nozzle arrays.
Where It Is Used
- Resort pool decks and beachfront terraces: One station feeds up to 200 nozzles across several zones, cooling open-air dining and lounging areas by 8-15°C without wetting furniture.
- Factory and warehouse floors: Continuous-duty operation holds mist pressure 24 hours a day, cutting heat stress at worker stations in buildings up to 5,000 m².
- Construction and mining dust suppression: The variable-flow pump sustains the higher water volume that coarse dust-suppression droplets require while holding line pressure at 150 bar.
- Greenhouses and livestock barns: Precise pressure regulation keeps droplets in the 5-15 micron range needed for evaporative cooling without soaking foliage or bedding.
Environments served
- Resort pool decks and beachfront terraces
- Factory and warehouse floors
- Construction and mining dust suppression
- Greenhouses and livestock barns
Core Parameters
| Max Pressure | 150 bar (2,175 PSI) |
|---|---|
| Flow Rate | 8-25 L/min (variable) |
| Motor Power | 5.5 kW, 380V 3-phase |
| Pump Material | 316L Stainless Steel |
| Nozzle Capacity | Up to 200 nozzles |
| Dimensions | 800 x 600 x 1200 mm |
| Weight | 145 kg |
| Noise Level | < 55 dB(A) |
| Protection Rating | IP65 |
| Filtration | 5-stage (50/20/5/1/0.5 micron) |
| Communication | Modbus RTU, TCP/IP, 4G optional |
| Operating Temp | -10°C to 55°C |
MG-PRO 1500 pump station vs Fixed-speed piston pump station
| MG-PRO 1500 pump station | Fixed-speed piston pump station | |
|---|---|---|
| Pressure stability | Holds 150 bar within ±1 bar through VFD feedback control | Swings 10-20 bar as nozzles open and close |
| Energy at part load | Motor speed follows demand; typically 30-40% less power at half load | Runs at full speed whenever energised |
| Pump head material | 316L stainless steel, tolerant of saline and chemical water | Brass or cast iron, corrodes on hard or saline water |
| Nozzle capacity | Up to 200 nozzles from a single unit | Typically 40-80 nozzles before pressure drops |
| Duty cycle | 24/7 continuous rated with automatic low-water shutdown | Intermittent duty; overheats in continuous service |
| Noise | Below 55 dB(A) in a sound-dampened enclosure | 75-85 dB(A) on an open frame |
| Maintenance interval | Oil change every 2,000 operating hours with 5-stage filtration | Seal and valve replacement every 500-800 hours |
Key Features
- 150 bar max operating pressure
- VFD motor for energy-efficient variable speed control
- 316L stainless steel pump head, valves, and fittings
- IP65 weatherproof enclosure with active cooling
- Integrated 5-stage water filtration system
- Modbus RTU / TCP for SCADA integration
- Automatic low-water shutdown protection
- Sound-dampened enclosure (< 55 dB)
MG-PRO 1500 High-Pressure Pump Station FAQ
How does the MG-PRO 1500 High-Pressure Pump Station high-pressure misting system work?
The MG-PRO 1500 High-Pressure Pump Station uses a 150-bar high-pressure pump to force water through 0.15mm ceramic nozzles, creating 5-15 micron droplets. These micro-droplets flash-evaporate in mid-air, absorbing 2,257 kJ of heat per liter of water. The result is 5-15°C cooling without wetting any surfaces.
What cooling performance can I expect from this system?
In controlled testing, 100Cooling high-pressure systems achieve 5-8°C actual temperature reduction and 8-15°C in perceived cooling. Performance depends on ambient humidity — best results in dry to moderately humid climates (RH below 70%). Each installation includes a site-specific performance estimate from our engineering team.
What maintenance is required for the misting system?
Minimal maintenance required: nozzle inspection every 6 months, filter cartridge replacement annually, pump oil change every 2,000 operating hours. The MG-IOT HUB provides proactive remote monitoring and sends automated maintenance alerts. Most installations run 12-18 months between professional service visits.
What warranty coverage is included with this system?
The MG-PRO 1500 High-Pressure Pump Station includes a 5 years. Our comprehensive warranty covers all pump station components, nozzles, and controllers. It includes parts replacement and remote technical support, with on-site service available through our certified partner network in 25+ countries.
How is the system installed and what are the requirements?
Installation is handled by our certified partner network across 25+ countries. The system requires a standard water connection, 220V/380V power supply, and structural mounting points for nozzles. Our 5-stage integrated filtration handles most water sources. Typical installation takes 2-5 days depending on site size. We provide comprehensive installation documentation and remote supervision.
Engineering Resources
Learn more about misting technology, selection criteria, and ROI
Need a Custom Configuration?
Our engineering team can design a bespoke system for your specific space, climate, and budget.
Get Engineering Consultation